Fire Doors: Keeping Your Home Safe from Fires

Welcome to Sun City.

Buildings are compartmentalized to delay the spread of fire from one area to another. These compartments are usually linked by fire doors to allow the flow of traffic around the building. Fire doors have two important functions in a fire; when closed they form a barrier to stop the spread of fire and when opened they provide a means of escape.


A well-designed timber fire door will delay the spread of fire and smoke without causing too much hindrance to the movement of people and goods.
Every fire door is therefore required to act as a barrier to the passage of smoke and/or fire to varying degrees depending upon its location in a building and the fire hazards associated with that building.
The main categories of fire doors are FD30 and FD60 fire doors which offer 30 and 60 minutes of fire protection.

Certification testing of timber fire doors

To determine the FD rating of fire doors, the manufacturers have their fire doors assessed by subjecting them to a test procedure as specified in BS 476-22.1987 or BS EN 1634-1:2014. Tests are made on complete door assemblies: ie. the fire door and doorframe with all the requisite hardware (e.g. locks, latches, hinges, etc). The assembly, or doors, as it is also known, is fixed in a wall representing its use in practice. It is important that the actual frame to be used is tested as well, should a door be tested in one type of frame and then used in another, no guarantee could be given of its performance under fire conditions.

The test procedure is fully described in the Standard and consists of exposing one face of the door to the heat conditions anticipated in a fire while observing the door for stability and integrity. The Standard requires the tests to be carried out with the upper part of the door under a small positive pressure, to simulate the conditions likely to occur in a fire. It also provides an objective method of establishing the loss of integrity of a fire door by the use of a combustible fibrous pad on the unexposed side of the door to see when it ignites.

As a fire door should be tested from each side to establish its performance with either face exposed to fire conditions, two specimens are required. It is reasonable to assume that all fire doors and doorframes manufactured to the same specification as the two specimen doors and frames will achieve the same fire-resisting properties.

Fire-resisting doors – door type for means of escape purposes

Integrity

Minutes [1]

Stability

Minutes [2]

Half-hour fire-resisting

30

30

One-hour fire-resisting

60

60

[1] Integrity failure is deemed to occur when cracks or other openings develop through which flames or hot gases can pass or when flaming occurs on the unexposed face.

[2] Stability failure is deemed to occur when the collapse of the specimen takes place.

Fire doors with a rating in excess of FD6O are rarely used on escape routes or to protect people but may be found where the preservation of property is important e.g. data storage areas where documents cannot be removed in the event of fire. Some of these doors have the appearance of timber but may be constructed with a mineral core. Expert assistance may be required to identify such door sets.

Identifying Fire Doors

Certified Fire Doors

Manufacturers can certify fire door sets, both for identification purposes and to guarantee their performance in a fire situation. The first step for the manufacturer is to construct a fire door set designed to a specification that, in their opinion, will resist a fire for a specified length of time. This door set will then be tested by an approved fire testing center and, if it is passed, any door sets constructed to that specification can be considered for certification.

Once the certification is approved, each similarly constructed door set will be identified by a label identifying the manufacturer, the date of manufacture, and the designated fire rating of the door type. This identification label is usually affixed to the top edge of the door. A color-coded plug may be inserted into the door, instead of or in addition to the label. For hospitals, fire doors display a disc at the top of each face of the door showing the designated fire performance as per Health Technical Memoranda (HTM) 58.

Identification marks can sometimes be removed or painted over during the installation or adjustment of a fire doorset but, if the work has been professionally carried out under the auspices of the BWF/FIRAS Accredited Fire Door Installers Scheme, the chance of this happening can be avoided.

There are two associations that have certifiable fire door systems, namely.

British Woodworking Federation Certifire fire door scheme

The British Woodworking Federation (BWF) is another major organization that provides fire door ratings. BWF fire ratings for fire door assemblies are stated in minutes and prefixed by the letters ‘FD’: e.g. FD30 refers to a 30-minute fire door or fire doors; in other words, one that offers at least 30 minutes of protection against fires.
The most commonly specified integrity levels are:

  • FD30 – 30 minutes
  • FD60 – 60 minutes
  • FD90 – 90 minutes
  • FD120 – 120 minutes

As part of the steps being taken by the BWF to simplify fire door identification and eliminate confusion in the specification, the existing FD20 rating is no longer available.

Every BWF-CERTIFIRE Fire Door Assembly carries a permanent and tamper-evident label. For more information, visit The British Woodworking Federation website or download the latest Scheme Directory for a listing of all members of the BWF-CERTIFIRE Fire Door & Doorset Scheme.

The former system used by BWF utilizing plastic plugs has been superseded but may still be in evidence in older buildings. The obsolete fire door identifications can be seen on the BWF obsolete card.

TRADA Q-Mark fire door scheme

The woodworking association BM TRADA uses a system known as Q-Mark, in which a series of colored plugs are inserted into the door to indicate the fire door type, member details, the scope of certification during specification and installation, and service history.

Nominal Fire Doors

Nominal fire doors are doorsets that are not certified but in the opinion of an assessor will hold back a fire for a specified period of time. Identifying nominal fire doors is very difficult but there are a number of clues that may indicate the door is a nominal fire door.

Is your door a fire door?

Older panel doors, especially if less than 44mm thick, are unlikely to be FD30. They could, however, have been upgraded or modified to achieve fire-resisting standards. These days you might find certified paneled fire doors with wood surfaces to fit into traditional homes.

Hollow flush doors using egg box or similar construction will not be FD30. This can be detected by the weight of the door because fire doors are much heavier than hollow doors. To check the weight of a door, instead of removing it, you can detach yourself closer and swing the door between your thumb and index finger. This gives a good indication of the weight of the door. Hollow doors are reasonably easy to detect using this method.

Fire doors will have automatic closing devices (fire door closers) fitted. Spring-loaded self-closing hinges and concealed Perko door closers with chains might also be in evidence.
Because of the weight of a fire door and to prevent it from warping, fire doors are usually fitted with three fire door hinges. The current BS EN standard does, however, allow two hinges in certain circumstances. There may be documentation that was supplied with a fire door giving you all the necessary information. 

Unfortunately, as there is no standard method of identifying fire doors other than the Q-Mark or the CERTIFIRE fire door schemes, insisting on written proof that a door meets all the necessary standards, for example, a test certificate, might still be necessary.

Fire Door Seals or Fire and Smoke Seals

Intumescent fire door seals should be fitted to the stiles and head of a fire-resisting door set.These seals are fitted into grooves cut into the door or the frame, or alternatively, can be surface mounted. As soon as the temperature in the vicinity of the strips exceeds 200°C, usually about 10-15 minutes after the start of a fire, the seal swells and seals the gaps between the door and frame.

  • As smoke spread is an even greater threat to life and property than flames, particularly in the early stages of a fire, fire doors might also have to be fitted with a ‘cold smoke’ seal to prevent the ingress of smoke around the door edges (such fire doors would be specified as FDs fire doors). Exceptions apply where the leakage of smoke is essential for detecting a fire early.
  • Combined smoke and intumescent seals are available.

Not all intumescent materials act in the same way. Low-pressure seals expand in all directions but provide little help to the door in resisting distortion under fire. Some high-pressure seals exert pressure mainly in one direction and provide some resistance to distortion of the door leaf under fire.

A further type of intumescent material, available in different grades, acts in all directions and generates some pressure. Fire door seals activate at temperatures that are above human survival levels. The following is information on the type or size of the intumescent fire door seal that should be used.

Type of fire door

Intumescent Seals

Intumescent Fire and Smoke Seals

30/30 Single action door

30/30 Double action door

10mm x 4mm

(Both sides and top)

10mm x 4mm

(Both sides and top)

30/30 Double pairs of doors

10mm x 4mm on one centre stile

10mm x 4mm on other stile, heads and back edges

60/60 Single action door

60/60 Double action door

20mm x 4mm

(Both sides and top)

20mm x 4mm

(Both sides and top)

60/60 Double pair of doors

20mm x 4mm on one centre stile

20mm x 4mm on other stile, heads and back edges

Most modern fire door seals combine the intumescent and cold smoke elements in one seal.

Grooves should be made slightly wider than the seals to allow for the pre-painting and shrinkage of timber.

Note: – It is advisable to ask fire door manufacturers what type of seal to use.

Fire Resisting Glazing

Glazing may range from a small vision panel in a door to a glazed screen for maximum light transmission and safety. Ordinary glass cracks when exposed to heat and is liable to fall out fairly early in a fire. Fire resisting glass can withstand exposure to the heat condition in a fire test for at least 60 minutes before it reaches a temperature high enough to soften it. This is mainly because, with clear FR glazing, nearly 50 per cent of the incident heat is transmitted through the glass by radiation.

The size of the glass and the method of its retention are important factors that influence its integrity. As the temperature approaches the softening point, a large sheet will tend to collapse earlier than a smaller one. On the unexposed face, beading retaining the glass is subjected to radiant and conducted heat through the glass and to convection currents at the top of the pane.

This can raise the temperature sufficiently to ignite timber beading after approximately 20 minutes. To delay the ignition of beading to 30 minutes, it is necessary either to provide protection by impregnation of a surface coating or a surface covering of non-combustible material or to fit a fire resistant glass secured using a fire resistant glazing system. This will hold the glass firmly in place during normal use, but in the event of fire, allows the intumescent material to expand, thereby securing and insulating the glass and protecting the surrounding timber. 

For longer periods of fire protection, an improved retention system for the glazing is required. The glass panel should be small and the method of fixing must ensure that no direct path can be created for the transference of hot gases.

Fore more detailed information, visit the Glass and Glazing Federation and download the Fire Resistant Glazing Best Practice Guide.

Upgrading of existing doors

Years ago, it was accepted practice to improve the performance of an existing door to a half-hour fire-check or fire-resisting standard, although in some cases it was more economical to replace the door rather than alter it. The doors were usually panel type or a light core flush type about 44mm thick: they require a facing on the risk side with a non combustible board.

It is now the accepted practice to fit new fire doors and fire doorsets in preference to upgrading them but this is not always an option, as in the case of historic/listed buildings, for example.These days you can configure and order entire fire doors with either 30 minutes (FD30) or 60 minutes (FD60) protection online. These fire doors can be configured with or without frame.

Suitability of doors for upgrading

Door type

Suitable?

Comments

Unframed, hollow core, flush

No

Too light and insubstantial

Framed, hollow core, flush

Framed, solid core, flush

Yes

If the core of flax board, timber, or solid chipboard

Ledged and braced

No

Insufficient thickness at the edges to accommodate an intumescent seal

Framed, pledged, and braced

Yes(20 mins only)

Extremely dependent on joints and fixings

Framed, solid with solid panels

Yes

Depends on thickness, minimum 44mm, and panel construction

Framed, solid with glazed panels

Yes

Depends on thickness, minimum 44mm, and type/installation of glazing

Methods of upgrading

There is no ‘one size fits all’ method of upgrading existing doors and the solution chosen will depend on the door construction, condition, situation and customer requirements. Techniques that have been successfully used in the past include:

Facing the door leaf with a non-combustible board

This is one of the easiest methods of upgrading, although it does create a visually unattractive result. It is, however, favoured by some heritage authorities as it a reversible process; removing the facing returns the leaf to its original condition. If used, facings should be applied symmetrically to each face (note that the increased thickness and weight may affect the door frame and ironmongery specification).

Sandwiching panels

For paneled doors, the weakest area is generally the panel itself. In many cases, the timber will be less than 10mm thick at the thinnest point. One method of upgrading is to remove the panels, split them through their thickness and insert a sandwich material – either an appropriate intumescent sheet or a non-combustible board. This is more difficult than other approaches but does enable the original finish to be maintained, which can be important for heritage projects.

Intumescent paper

Intumescent paper and cards can be used selectively to protect vulnerable areas such as the fielded area of paneled doors. The application thickness is controlled by the thickness of the paper but can be veneered to restore a timber finish.

Intumescent paints and varnishes

Intumescent paints and varnishes are available for use on timber-based fire resisting doorsets where a maximum performance of 30-minute integrity is required. These products require extremely specific application techniques and are reliant on the underlying condition of the doorset construction. Great care should be taken to ensure that full-scale test data for the product is both available and appropriate for the application in question.

It is likely that other upgrading measures will be required in conjunction with any of these measures.

Fire Door Furniture and Ironmongery

An important aspect of ensuring fire doors meet the required standard is the fitting of certified door furniture, or hardware, which is overlooked on many occasions. If you go to our page Fire Door Fittings and Ironmongery there is a detailed description of all the door furniture suitable for fire doors and the appropriate standards.

Maintenance of Fire Doors

Fire doors are engineered products that provide life and property-saving functions in the event of fire. It is important that they are regularly inspected and maintained to permit them to perform at their best on the one and only occasion when they are called upon to do so.

Doorsets fitted with hold-open devices or swing-free type closers should be closed daily, particularly overnight when there is likely to be low building occupancy. For busy 24/7 buildings (e.g. hospitals) fire doors should be closed at least weekly. All fire doors should close effectively from any angle of opening, using only the door closer.

There are a number of reasons why doors may fail to close:

  • Foreign bodies or other objects may be obstructing the door.
  • The smoke seals may be incorrectly fitted or damaged.
  • If a latch is fitted, it may be malfunctioning or require lubrication.
  • The closing device may need adjustment but this must only be done as a last resort and very carefully, to ensure that the door can be opened without undue force.

Intumescent seals should be checked regularly, at intervals not greater than 6 months, and damaged or missing ones replaced. To maintain the designated performance potential, replacement seals should be of the same brand, size, and type as the original. Any intumescent seal of the same size as the original, however, is better than none.

Mechanical items such as hinges, locks, latches, closers, floor springs, etc are likely to wear over time. Maintenance provisions should comply with the hardware supplier’s recommendations where these are known. Otherwise, locks and latches may require occasional light lubrication. Some hinges use self-lubricating bearings that will not need additional lubrication.

Where it is necessary to replace worn hardware on a fire door, the essential items should be replaced with products to the same specification as the original where possible. Otherwise, hinges, latches, locks, flush bolts, closers, and other items of load-bearing or securing hardware should be of the same type and size as the original items and should have been proven for use in timber fire-rated door sets of the required performance.

Hardware that has been successfully tested in metal door sets may not be suitable for use with timber door sets. Intumescent gaskets may have been used under hinge blades, locks/latches for end plates, strike plates, and/or with closer fittings and in flush bolt recesses. These gaskets should ideally be replaced if possible with gaskets of the same material; alternatively, if undamaged, they should be retained and reused with the new fittings. Intumescent gaskets or mastics used for these applications are usually the low-pressure type. Redundant hardware should be carefully removed.